APC BK350 uninterruptible power supply (UPS) 0.35 kVA 210 W - UPS hardware - Electrical accessories & UPS - Home - MT Shop
Back
For illustrative purpose only

APC BK350 uninterruptible power supply (UPS) 0.35 kVA 210 W

Manufacturer: APC Product Code: 21814659 EAN: 00731304016298 MPN: BK350
APC BK350, 0.35 kVA, 210 W, 50/60 Hz, 1020 J, 4.7 min, 18.1 min
Read more...

Product Information


Information
Manufacturer APC
Product code 21814659
EAN 00731304016298
Manufacturer part number BK350
Category UPS hardware
Features
Output power capacity 0.35 kVA
Output power 210 W
Input frequency 50/60 Hz
Audible alarm(s) Y
Cable length 1.8 m
Certification FCC Part 68/TUV
Input connection type NEMA 5-15P
Power
Surge energy rating 1020 J
Nominal input voltage 120 V
Battery
Typical backup time at full load 4.7 min
Typical backup time at half load 18.1 min
Battery recharge time 8 h
Hot-swap battery Y
Design
Product colour Beige
LED indicators Y
Performance
Safety UL/FCC/CE/C-Tick
Operational conditions
Operating temperature (T-T) 0 - 40 °C
Storage temperature (T-T) -15 - 45 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Operating altitude 0 - 3000 m
Operating temperature (T-T) 0 - 40 °F
Weight & dimensions
Weight 5.98 kg
Package weight 6.36 kg
Logistics data
Products per pallet 80 pc(s)
Other features
Output connections 3 x NEMA 5-15R
Dimensions (WxDxH) 91 x 284 x 165 mm
Nominal output voltage 120 V
Package dimensions (WxDxH) 175 x 357 x 263 mm
Non-operating relative humidity (non-condensing) 0 - 95%
Weight (imperial) 5.67 kg (12.5 lbs)

Product Description


Data line surge protection
Protects connected loads from surges, spikes, lightning, and other power disturbances.

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment

LED status indicators
Quickly understand unit and power status with visual indicators.

Audible Alarms
Provides notification of changing utility power and UPS conditions.

Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery replacement without tools
Allows quick, easy battery replacement.

Cold-start capable
Provides temporary battery power when the utility power is out.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.

Resettable circuit breakers
Enables a quick recovery from overload events.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.

MT Shop © 2025