For illustrative purpose only
APC BX950MI-GR uninterruptible power supply (UPS) Line-Interactive 0.95 kVA 520 W 4 AC outlet(s)
APC BX950MI-GR, Line-Interactive, 0.95 kVA, 520 W, Sine, 140 V, 300 V
Read more...
Read more...
Product Information
Information | |
---|---|
Manufacturer | APC |
Product code | 074113000 |
EAN | 00731304410850 |
Manufacturer part number | AUAPCLI1TB950GR |
Category | UPS hardware |
Features | |
---|---|
UPS topology | Line-Interactive |
Output power capacity | 0.95 kVA |
Output power | 520 W |
Waveform | Sine |
Input operation voltage (min) | 140 V |
Input operation voltage (max) | 300 V |
Input frequency | 50/60 Hz |
Output operation voltage (min) | 230 V |
Output operation voltage (max) | 230 V |
Output frequency | 50/60 Hz |
Output frequency regulation | 0.5 Hz |
Output voltage regulation | 10% |
Automatic Voltage Regulation (AVR) | Y |
Input power factor | 0.54 |
Surge protection | Y |
Audible alarm(s) | Y |
Audible alarm modes | Low battery alarm |
Cable length | 1.2 m |
Certification | CB Meet EN62040-1 / CE / IEC-62040-1 / IEC-62040-2 |
Harmonized System (HS) code | 85078000 |
Power | |
---|---|
Surge energy rating | 273 J |
Display | |
---|---|
Response time | 6 ms |
Other features | |
---|---|
Noise level | 40 dB |
USB 2.0 ports quantity | 1 |
Ports & interfaces | |
---|---|
AC outlet types | Type F |
Power plug | Type F |
AC outlets quantity | 4 AC outlet(s) |
USB port | Y |
USB port type | USB Type-B |
Ethernet LAN (RJ-45) ports | 2 |
Battery | |
---|---|
Battery technology | Sealed Lead Acid (VRLA) |
Typical backup time at full load | 1 min |
Typical backup time at half load | 6.5 min |
Battery life (max) | 2 year(s) |
Battery recharge time | 8 h |
Design | |
---|---|
Form factor | Compact |
Product colour | Black |
LED indicators | Y |
International Protection (IP) code | IP20 |
Operational conditions | |
---|---|
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 3000 m |
Sustainability | |
---|---|
Sustainability certificates | RoHS |
Weight & dimensions | |
---|---|
Width | 120 mm |
Depth | 355 mm |
Height | 160 mm |
Weight | 6.1 kg |
Package weight | 6.6 kg |
Packaging data | |
---|---|
Package width | 197 mm |
Package depth | 430 mm |
Package height | 250 mm |
Packaging content | |
---|---|
Cables included | Input power cable |
Manual | Y |
Product Description
Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
PowerChute Personal Edition OS Compatibility
This software supports numerous operating systems and processors.
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status display
Quickly understand unit and power status with visual indicators.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
PowerChute Personal Edition OS Compatibility
This software supports numerous operating systems and processors.
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status display
Quickly understand unit and power status with visual indicators.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment