For illustrative purpose only
APC Smart UPS 0.75 kVA 500 W
APC Smart UPS, 0.75 kVA, 500 W, 50/60 Hz, 340 J, 4.8 min, 16.4 min
Read more...
Read more...
Select | Supplier | Availability | Price | ETA |
---|---|---|---|---|
M2 | 2 | 554.61 € | ~ Fr 09.05 | |
E1 | 0 | 660.45 € | Ask for availability |
Estimated delivery time of the product from selected supplier: ~ Fr 09.05
554.61 €
tk
Returns Policy
14-day money back guaranteeFlexible Payment Options
- Payment by invoice or e-invoice possible for individuals, companies and public authorities
- Payment via bank link - Coop, LHV, SEB, Swedbank, Luminor, Citadele
- Credit card payment
Pay later or in installments
Installment calculator
-
MTS Järelmaks
100 € - 10 000 € -
Liisi Järelmaks
10 € - 25 000 € -
Inbank järelmaks
100 € - 10 000 € -
LHV Järelmaks
50 € - 15 000 €
Monthly payment:
17.05 €
All calculations made on the calculator supplied on this site are guidelines only and are subject to confirmation at the time of finalising any transactions.
Product Information
Information | |
---|---|
Manufacturer | APC |
Product code | 16546728 |
EAN | 00731304253365 |
Manufacturer part number | SUA750IX38 |
Category | UPS hardware |
Features | |
---|---|
Output power capacity | 0.75 kVA |
Output power | 500 W |
Input frequency | 50/60 Hz |
Audible alarm(s) | Y |
Certification | C-tick,CE,EN 50091-1,EN 50091-2,EN 55022 Class A,GOST,IEC 60950,VDE |
Harmonized System (HS) code | 85078000 |
Input connection type | IEC-320-C14 inlet |
Power | |
---|---|
Surge energy rating | 340 J |
Nominal input voltage | 230 V |
Battery | |
---|---|
Typical backup time at full load | 4.8 min |
Typical backup time at half load | 16.4 min |
Battery recharge time | 3 h |
Hot-swap battery | Y |
Design | |
---|---|
Product colour | Black |
LED indicators | Y |
Operational conditions | |
---|---|
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 45 °C |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 0 - 15000 m |
Weight & dimensions | |
---|---|
Weight | 13.2 kg |
Package weight | 14.6 kg |
Other features | |
---|---|
Output connections | 6 x IEC 320 C13 1 x IEC Jumpers |
Dimensions (WxDxH) | 137 x 358 x 157 mm |
Nominal output voltage | 230 V |
Package dimensions (WxDxH) | 270 x 500 x 290 mm |
Product Description
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent Battery Management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to
battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Cold-start capable
Provides temporary battery power when the utility power is out.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Generator Compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Network manageable
Provides remote management of the UPS over the network.
SmartSlot
Customize UPS capabilities with management cards.
Audible Alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial Connectivity
Provides management of the UPS via a serial port.
USB Connectivity
Provides management of the UPS via a USB port (not available on all models).
Disconnected battery notification
Warns when a battery is not available to provide backup power.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers
Enables a quick recovery from overload events.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent Battery Management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to
battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Cold-start capable
Provides temporary battery power when the utility power is out.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Generator Compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Network manageable
Provides remote management of the UPS over the network.
SmartSlot
Customize UPS capabilities with management cards.
Audible Alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial Connectivity
Provides management of the UPS via a serial port.
USB Connectivity
Provides management of the UPS via a USB port (not available on all models).
Disconnected battery notification
Warns when a battery is not available to provide backup power.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers
Enables a quick recovery from overload events.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.
Related products
Al. 23.23 €
Al. 81.23 €
Al. 44.27 €
796.66 €