APC Smart-UPS Line-Interactive 1 kVA 640 W 4 AC outlet(s)
APC Smart-UPS, Line-Interactive, 1 kVA, 640 W, Sine, 151 V, 302 V
Read more...
Read more...
Select | Supplier | Availability | Price | ETA |
---|---|---|---|---|
F | 1 | 928.41 € | ~ Mo 31.03 | |
E1 | 0 | 1 682.04 € | ~ Fr 25.04 |
Estimated delivery time of the product from selected supplier: ~ Mo 31.03
928.41 €
tk
Returns Policy
14-day money back guaranteeFlexible Payment Options
- Payment by invoice or e-invoice possible for individuals, companies and public authorities
- Payment via bank link - Coop, LHV, SEB, Swedbank, Luminor, Citadele
- Credit card payment
Pay later or in installments
Installment calculator
-
MTS Järelmaks
100 € - 10 000 € -
Liisi Järelmaks
10 € - 25 000 € -
Inbank järelmaks
100 € - 10 000 € -
LHV Järelmaks
50 € - 15 000 €
Monthly payment:
28.55 €
All calculations made on the calculator supplied on this site are guidelines only and are subject to confirmation at the time of finalising any transactions.
Product Information
Information | |
---|---|
Manufacturer | APC |
Product code | 03193628 |
EAN | 07313041238978 |
Manufacturer part number | SUA1000RMI1U |
Category | UPS hardware |
Features | |
---|---|
UPS topology | Line-Interactive |
Output power capacity | 1 kVA |
Output power | 640 W |
Waveform | Sine |
Input operation voltage (min) | 151 V |
Input operation voltage (max) | 302 V |
Input frequency | 50/60 Hz |
Surge protection | Y |
Audible alarm(s) | Y |
Certification | C-tick, CE, EN 50091-1, EN 50091-2, GOST, VDE, PEP, EOLI |
Input connection type | IEC-320 C14 |
Power | |
---|---|
Surge energy rating | 480 J |
Nominal input voltage | 230 V |
Other features | |
---|---|
Noise level | 55 dB |
Nominal output voltage | 230 V |
Ports & interfaces | |
---|---|
AC outlet types | C13 coupler |
Power plug | C14 coupler |
AC outlets quantity | 4 AC outlet(s) |
Number of output IEC jumpers | 2 |
USB port | Y |
Serial interface | Y |
Serial interface type | RS-232 |
SmartSlot | Y |
Interface | DB-9 RS-232, SmartSlot, USB |
Battery | |
---|---|
Battery technology | Sealed Lead Acid (VRLA) |
Battery capacity | 216 VAh |
Typical backup time at full load | 5.4 min |
Typical backup time at half load | 14.5 min |
Battery life (max) | 6 year(s) |
Battery recharge time | 2 h |
Hot-swap battery | Y |
Automatic battery test | Y |
Design | |
---|---|
Form factor | Rackmount |
Product colour | Black |
Rack capacity | 1U |
LED indicators | Battery replacement |
Operational conditions | |
---|---|
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 45 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 0 - 15000 m |
Sustainability | |
---|---|
Sustainability certificates | RoHS |
Weight & dimensions | |
---|---|
Width | 432 mm |
Depth | 660 mm |
Height | 44 mm |
Weight | 21.8 kg |
Package weight | 25.4 kg |
Packaging content | |
---|---|
Rack mount kit | Y |
Cables included | RS-232, USB cable |
Manual | Y |
Packaging data | |
---|---|
Software CD | Y |
Package width | 559 mm |
Package depth | 775 mm |
Package height | 191 mm |
Logistics data | |
---|---|
Products per pallet | 8 pc(s) |
Product Description
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Cold-start capable
Provides temporary battery power when the utility power is out.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Network manageable
Provides remote management of the UPS over the network.
Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial Connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Disconnected battery notification
Warns when a battery is not available to provide backup power.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure® Manager.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers
Enables a quick recovery from overload events.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Cold-start capable
Provides temporary battery power when the utility power is out.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Network manageable
Provides remote management of the UPS over the network.
Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial Connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Disconnected battery notification
Warns when a battery is not available to provide backup power.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure® Manager.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers
Enables a quick recovery from overload events.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.