APC SRTG5KXLI uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA 5000 W 3 AC outlet(s)
APC SRTG5KXLI, Double-conversion (Online), 5 kVA, 5000 W, Sine, 100 V, 285 V
Read more...
Read more...
Product Information
Information | |
---|---|
Manufacturer | APC |
Product code | 357248499 |
EAN | 00731304411802 |
Manufacturer part number | SRTG5KXLI |
Category | UPS hardware |
Features | |
---|---|
UPS topology | Double-conversion (Online) |
Output power capacity | 5 kVA |
Output power | 5000 W |
Waveform | Sine |
Input operation voltage (min) | 100 V |
Input operation voltage (max) | 285 V |
Input frequency | 40/70 Hz |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output frequency | 50/60 Hz |
Crest factor | 3:1 |
ECO mode | Y |
Emergency Power Off (EPO) | Y |
Output voltage Total Harmonic Distortion (THD) | 2% |
Audible alarm(s) | Y |
Audible alarm modes | Alarm when on battery, Low battery alarm, Overload alarm |
Certification | CE, EN/IEC 62040-1 |
Power | |
---|---|
Surge energy rating | 600 J |
Other features | |
---|---|
Noise level | 55 dB |
Ports & interfaces | |
---|---|
AC outlet types | C13 coupler, C19 coupler |
AC outlets quantity | 3 AC outlet(s) |
USB port | Y |
Serial interface | Y |
Ethernet LAN (RJ-45) ports | 1 |
Emergency Power Off (EPO) connector | Y |
SmartSlot | Y |
Battery | |
---|---|
Battery technology | Sealed Lead Acid (VRLA) |
Battery voltage | 96 V |
Battery life (max) | 5 year(s) |
Battery recharge time | 4 h |
Hot-swap battery | Y |
Automatic battery test | Y |
Cold start | Y |
Design | |
---|---|
Form factor | Compact |
Product colour | Black |
Rack capacity | 4U |
Display type | LCD |
LED indicators | Y |
International Protection (IP) code | IP20 |
Operational conditions | |
---|---|
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 45 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2011 m |
Non-operating altitude | 0 - 15240 m |
Weight & dimensions | |
---|---|
Width | 440 mm |
Depth | 620 mm |
Height | 178 mm |
Weight | 51.9 kg |
Package weight | 59 kg |
Packaging data | |
---|---|
Package width | 590 mm |
Package depth | 790 mm |
Package height | 275 mm |
Product Description
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Cold-start capable
Provides temporary battery power when the utility power is out.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input Power Factor Correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
SmartSlot
Customize UPS capabilities with management cards.
Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Serial connectivity
Provides management of the UPS via a serial port.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
LED status indicators
Quickly understand unit and power status with visual indicators.
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Cold-start capable
Provides temporary battery power when the utility power is out.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input Power Factor Correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
SmartSlot
Customize UPS capabilities with management cards.
Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Serial connectivity
Provides management of the UPS via a serial port.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
LED status indicators
Quickly understand unit and power status with visual indicators.