APC SY64K96H-PD uninterruptible power supply (UPS) 64 kVA 64000 W - UPS hardware - Electrical accessories & UPS - Home - MT Shop
Back
For illustrative purpose only

APC SY64K96H-PD uninterruptible power supply (UPS) 64 kVA 64000 W

Manufacturer: APC Product Code: 229214757 MPN: SY64K96H-PD
APC SY64K96H-PD, 64 kVA, 64000 W, 0.02%, 0.05%, 63 dB, Sealed Lead Acid (VRLA)
Read more...

Product Information


Information
Manufacturer APC
Product code 229214757
Manufacturer part number SY64K96H-PD
Category UPS hardware
Features
Output power capacity 64 kVA
Output power 64000 W
Emergency Power Off (EPO) Y
Output voltage Total Harmonic Distortion (THD) 0.02%
Input current Total Harmonic Distortion (THD) 0.05%
Audible alarm(s) Y
Certification EN 50091-1,EN/IEC 62040-3,EN/IEC 62040-1-1,FCC 15 A,VFI-SS-111
Input connection type 3PH + N + G
Other features
Noise level 63 dB
Output connections 1x 3PH + N + G
Battery
Battery technology Sealed Lead Acid (VRLA)
Battery recharge time 3.50 h
Design
Product colour Black
Operational conditions
Operating temperature (T-T) 0 - 40 °C
Storage temperature (T-T) -15 - 40 °C
Operating relative humidity (H-H) 0 - 95%
Storage relative humidity (H-H) 0 - 95%
Operating altitude 0 - 999.9 m
Non-operating altitude 0 - 15000 m
Weight & dimensions
Width 1200 mm
Depth 1070 mm
Height 1991 mm
Weight 1454 kg
Power
Battery type VRLA
Nominal input voltage 400 V
Ports & interfaces
Interface SmartSlot

Product Description


Audible alarms
Provide notification of changing flywheel conditions

InfraStruXure Central compatible
Enables centralized management via APC InfraStruXure® Central.

Modular design
Increases adaptability with an open architecture configurable to any IT environment.

Modular design
Modular construction - can be deployed as a non-standby and migrate to a standby (UPS) system.

LCD display
Alpha-Numeric Display which displays system parameters and alarms.

SmartSlot
Customize UPS capabilities with management cards.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.

Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery modules connected in parallel
Delivers higher availability through redundant batteries.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Audible alarms
Provides notification of changing utility power and UPS conditions.

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.

MT Shop © 2025