PowerWalker AVR 1500 SIV FR voltage regulator 2 AC outlet(s) 110-280 V Black
PowerWalker AVR 1500 SIV FR, 110-280 V, 50-60 Hz, 1.5 kVA, 1200 W, 2 AC outlet(s), 312 J
Read more...
Read more...
Product Information
| Information | |
|---|---|
| Manufacturer | PowerWalker |
| Product code | 22880335 |
| EAN | 04260074977042 |
| Manufacturer part number | AVR 1500/SIV |
| Category | Other UPS supplies and accessories |
Product Description
PowerWalker AVR 1500 SIV FR
PowerWalker AVR SIV Series are automatic voltage regulators with selectable input voltage 150-270VAC or wide 110-280VAC. It provides output voltage within allowed limit of +/-10% (207-253VAC) through boost and buck stabilizers. The built-in thermal sensor provides over-temperature protection and recover, while abnormal situation is eliminated.
The device works in following modes depending on input voltage:
- Input 252-270/280V – buck mode -10% in regards to input voltage
- Input 207-252VAC – normal operation
- Input 173-211VAC – first boost +20%
- Input 110/150-178VAC – second boost +40%
- Input <110VAC in wide range or <150VAC in normal mode – AVR off
Additionally you can turn on protection delay function which will increase protection reaction time from 10s to 3 minutes for less sensitive devices.
PowerWalker AVR SIV Series are automatic voltage regulators with selectable input voltage 150-270VAC or wide 110-280VAC. It provides output voltage within allowed limit of +/-10% (207-253VAC) through boost and buck stabilizers. The built-in thermal sensor provides over-temperature protection and recover, while abnormal situation is eliminated.
The device works in following modes depending on input voltage:
- Input 252-270/280V – buck mode -10% in regards to input voltage
- Input 207-252VAC – normal operation
- Input 173-211VAC – first boost +20%
- Input 110/150-178VAC – second boost +40%
- Input <110VAC in wide range or <150VAC in normal mode – AVR off
Additionally you can turn on protection delay function which will increase protection reaction time from 10s to 3 minutes for less sensitive devices.