For illustrative purpose only
Salicru SLC-5000-TWIN PRO2
Salicru SLC-5000-TWIN PRO2, Double-conversion (Online), 5 kVA, 5000 W, 110 V, 276 V, 50/60 Hz
Read more...
Read more...
Select | Supplier | Availability | Price | ETA |
---|---|---|---|---|
E1 | 0 | 2 701.56 € | ~ Mo 21.04 |
Estimated delivery time of the product from selected supplier: ~ Mo 21.04
2 701.56 €
tk
Returns Policy
14-day money back guaranteeFlexible Payment Options
- Payment by invoice or e-invoice possible for individuals, companies and public authorities
- Payment via bank link - Coop, LHV, SEB, Swedbank, Luminor, Citadele
- Credit card payment
Pay later or in installments
Installment calculator
-
MTS Järelmaks
100 € - 10 000 € -
Liisi Järelmaks
10 € - 25 000 € -
Inbank järelmaks
100 € - 10 000 € -
LHV Järelmaks
50 € - 15 000 €
Monthly payment:
83.07 €
All calculations made on the calculator supplied on this site are guidelines only and are subject to confirmation at the time of finalising any transactions.
Product Information
Information | |
---|---|
Manufacturer | Salicru |
Product code | 2210239721 |
EAN | 08436035922680 |
Manufacturer part number | 699CB000002 |
Category | UPS hardware |
Features | |
---|---|
UPS topology | Double-conversion (Online) |
Output power capacity | 5 kVA |
Output power | 5000 W |
Input operation voltage (min) | 110 V |
Input operation voltage (max) | 276 V |
Input frequency | 50/60 Hz |
Output operation voltage (min) | 208 V |
Output operation voltage (max) | 240 V |
Output frequency regulation | 4 Hz |
Output voltage regulation | 1% |
Number of input phases | 1 |
Number of output phases | 1 |
Input power factor | 0.99 |
Output power factor | 1 |
Crest factor | 3:1 |
ECO mode | Yes |
Emergency Power Off (EPO) | Yes |
Overload capacity (10 minutes) | 110% |
Overload capacity (1 minute) | 130% |
Output voltage Total Harmonic Distortion (THD) | 4% |
Input current Total Harmonic Distortion (THD) | 4% |
Total Harmonic Distortion (THD) (linear load) | 1% |
Total Harmonic Distortion (THD) (non-linear load) | 4% |
Surge protection | Yes |
Power protection features | Under voltage |
Maximum number of paralleling UPSs | 3 |
Synchronisation with mains | 4 Hz |
Synchronisation without mains | 0.1 Hz |
Temperature voltage compensation | Yes |
Harmonized System (HS) code | 85078000 |
Power | |
---|---|
Efficiency | 94% |
Battery type | AGM |
Other features | |
---|---|
Noise level | 60 dB |
Maintenance-free | Yes |
USB 2.0 ports quantity | 1 |
Bypass | Hybrid, Nill |
I/O ports | Intelligent slot |
Ports & interfaces | |
---|---|
AC outlet types | C13 coupler |
AC outlets quantity | 2 AC outlet(s) |
Number of output IEC jumpers | 2 |
USB port | Yes |
Serial interface | Yes |
Serial interface type | RS-232 |
RS-232 ports | 1 |
Parallel ports quantity | 3 |
Emergency Power Off (EPO) connector | Yes |
Battery | |
---|---|
Battery technology | Lead-Calcium (Pb-Ca) |
Battery recharge time | 7 h |
Automatic battery test | Yes |
Cold start | Yes |
Off-mode charging | Yes |
Design | |
---|---|
Form factor | Tower |
Product colour | Black |
Cooling type | Active |
Display type | LCD |
LED indicators | Yes |
Performance | |
---|---|
Built-in fan | Yes |
Safety | EN 62040-1; EN 60950-1 |
Operational conditions | |
---|---|
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 5000 m |
Weight & dimensions | |
---|---|
Width | 250 mm |
Depth | 592 mm |
Height | 576 mm |
Weight | 82 kg |
Product Description
Salicru's SLC TWIN PRO2 series UPS systems feature on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage. The systems come in a tower format and are available in power ratings of 4, 5, 6, 8, 10, 15 and 20 kVA. The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 4 to 20 kVA and a three-phase input of 8 to 20 kVA. All devices with single-phase input provide a unitary output power factor (1), the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant. The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance. (1) Except 15 and 20 kVA I / I models
Related products
Al. 64.05 €
Al. 728.05 €
867.79 €